Catalogo Bertolotto Petra

4 Come scegliere una PORTA BLINDATA LE PORTE BLINDATE DELLA COLLEZIONE PETRA SONO CONTROLLATE E CERTIFICATE PER GARANTIRE LE SEGUENTI CARATTERISTICHE PRESTAZIONALI: RESISTENZA ALL’EFFRAZIONE. LA PORTA BLINDATA SI DISTINGUE PER LA CAPACITÀ DI RESISTERE AI TENTATIVI DI INTRUSIONE, A CUI DEVE RISPONDERE CON ELEMENTI DI CHIUSURA E SUPERFICI ANTISCASSO. QUESTA CAPACITÀ DI PROTEZIONE VIENE VALUTATA CONFRONTANDO E INTERSECANDO PARAMETRI DIVERSI. ISOLAMENTO ACUSTICO. I SERRAMENTI CHE DIVIDONO L’INTERNO DALL’ESTERNO (COMPRESA LA PORTA DI INGRESSO) DEVONO PROTEGGERE L’AMBIENTE INTERNO DAI RUMORI ESTERNI ALL’ABITAZIONE. QUESTA CAPACITÀ DI PROTEZIONE SI MISURA CALCOLANDO LA QUANTITÀ DI dB ABBATTUTI DALL’ELEMENTO DIVISORIO. TRASMITTANZA TERMICA. I SERRAMENTI CHE DIVIDONO L’INTERNO DALL’ESTERNO (COMPRESA LA PORTA DI INGRESSO) DEVONO ISOLARE L’AMBIENTE INTERNO DAL FREDDO (O CALDO) ESTERNO, E PROTEGGERE DALLE INTEMPERIE. QUESTA CAPACITÀ DI PROTEZIONE SI MISURA CALCOLANDO LA DISPERSIONE DEL CALORE ATTRAVERSO L’ELEMENTO DIVISORIO, OVVERO LA SUA TRASMITTANZA TERMICA, CHE È INVERSAMENTE PROPORZIONALE AL GRADO DI ISOLAMENTO: MINORE TRASMITTANZA CORRISPONDE AD UN MAGGIORE ISOLAMENTO, QUINDI AD UN MAGGIORE RISPARMIO DI ENERGIA E AD UN MAGGIORE CONFORT. MODELLI MODELS RESISTENZA ALL’EFFRAZIONE SECONDO LA NORMA UNI EN 1627 BURGLAR RESISTANT ACCORDING TO SPECIFICATIONS UNI EN 1627 PERMEABILITA’ ALL’ARIA UNI EN 12207 AIR PERMEABILITY UNI EN 122027 RESISTENZA AL CARICO DEL VENTO UNI EN 12211:2001 UNI EN 12210:2000 WIND RESISTANCE UNI EN 12211:2001 UNI EN 12210:2000 TENUTA D’ACQUA UNI EN 12208:2000 WATER RESISTANCE UNI EN 12208:2000 ABBATTIMENTO ACUSTICO SOUNDPROOFING TRASMITTANZA TERMICA THERMAL TRANSMITTANCE SECUR CLASSE 3 CLASSE 3 CLASSE C5 CLASSE 1A 40dB U=1,8 TITANO CLASSE 4 CLASSE 3 CLASSE C5 CLASSE 2A 43dB U=1,8 FORTEZZA CLASSE 4 CLASSE 3 CLASSE C5 CLASSE 2A 43dB U=1,8 TITANO EXIT CLASSE 3 CLASSE C4 CLASSE 2A 39dB U=1,8 FIRE 30 E 60 CLASSE 3 CLASSE C5 CLASSE 2A VALORI INTESI PER PORTE AD UN’ANTA SUMMARY VALUES FOR A SINGLE DOOR THE REINFORCED DOORS FROM THE PETRA COLLECTION ARE CHECKED AND CERTIFICATED TO GUARANTEE THE FOLLOWING PERFORMANCE FEATURES: HIGH SECURITY. THE REINFORCED DOOR FEATURES HIGH RESISTANCE TO INTRUDERS WITH BURGLAR PROOF LOCKS AND SURFACES. THIS LEVEL OF SECURITY IS ACHIEVED THROUGH THE ASSESSMENT AND COMPARISON OF SEVERAL PARAMETERS. SOUNDPROOFING. DOORS (INCLUDING THE FRONT DOOR) ARE THE INTERFACE BETWEEN THE INSIDE AND OUTSIDE WORLDS AND SHOULD PROTECT THE INTERNAL ENVIRONMENT FROM EXTERNAL NOISE. THIS LEVEL OF PROTECTION IS ACHIEVED BY MEASURING THE DB DEADENED BY THE DOOR UNIT. HEAT INSULATION. DOORS ANDWINDOWS THAT SEPARATE THE INSIDE FROMOUTSIDE (INCLUDING THE FRONT DOOR) MUST INSULATE THE INTERNAL ENVIRONMENT FROM EXTERNAL COLD (OR HEAT) AND PROTECT AGAINST BAD WEATHER. THIS LEVEL OF PROTECTION IS MEASURED BY CALCULATING HEAT DISPERSION THROUGH THE DOOR UNIT, THE LEVEL OF THERMAL TRANSMITTANCE IS INVERSELY PROPORTIONATE TO THE LEVEL OF INSULATION: THE LOWER THE THERMAL TRANSMITTANCE THE HIGHER THE LEVEL OF INSULATION, MAKING THE DOOR MORE ENERGY EFFICIENT. How to choose a REINFORCED DOOR

RkJQdWJsaXNoZXIy NzM3NTE=